| == Zweck ==
| |
|
| |
| Testen von und mit [[wikipedia:en:10 Gigabit Ethernet|10 Gigabit]] foo
| |
|
| |
| == Gerät == | | == Gerät == |
|
| |
|
| ; hergestellt von: Dell | | ; hergestellt von: Dell |
| ; Modell: [[wikipedia:en:Dell Networking#N4000: 10Gbit multi-layer switches | N]][https://www.dell.com/support/home/de-de/product-support/product/networking-n4000-series/docs 4000] | | ; Modell: [[wikipedia:en:Dell Networking#N4000: 10Gbit multi-layer switches | N]][https://www.dell.com/support/home/de-de/product-support/product/networking-n4000-series/docs 4000] |
| ; [https://geizhals.de/a1539227.html Typ]: N4032 | | ; Typ: N4032 |
| | |
| === Dokumentation für das Gerät ===
| |
| | |
| * [https://i.dell.com/sites/doccontent/shared-content/data-sheets/en/Documents/Dell_Networking_N4000_Series_SpecSheet.pdf SpecSheet Dell Networking N4000 Series]
| |
| * [https://dl.dell.com/manuals/all-products/esuprt_ser_stor_net/esuprt_networking/esuprt_net_fxd_prt_swtchs/networking-n4000-series_administrator-guide10_en-us.pdf Administrator Guide]
| |
| * [https://dl.dell.com/manuals/all-products/esuprt_ser_stor_net/esuprt_networking/esuprt_net_fxd_prt_swtchs/networking-n4000-series_user's-guide11_en-us.pdf CLI reference guide]
| |
|
| |
|
| === Software für das Gerät === | | === Software für das Gerät === |
|
| |
|
| === Einrichtung vom Gerät === | | === Einstellungen vom Gerät === |
| | |
| ==== Möglichkeit zur Verwendung von mehreren Geräten als Stack ====
| |
| | |
| Wenn möglich, sollen 2 Geräte als Stack genutzt werden.
| |
| Als Stack wird es ermöglicht, dass nur ein Gerät konfiguriert werden muss. Das andere Gerät übernimmt die Firmware? und die Konfiguration.
| |
| | |
| ==== Einrichtung einer Anmeldung per SSH ====
| |
| | |
| <nowiki>
| |
| enable
| |
| configure
| |
| interface out-of-band
| |
| ip address 10.1.0.189 255.255.255.0 0.0.0.0
| |
| exit
| |
| ip telnet server disable
| |
| ip ssh server
| |
| exit
| |
| </nowiki>
| |
| | |
| <nowiki>
| |
| write
| |
| </nowiki>
| |
| | |
| ==== Verwaltung Konfiguration Bedienung ====
| |
| | |
| Beim Gerät kann seriell, oder per SSH angemeldet werden.
| |
| | |
| Anmeldung per SSH
| |
| : <code>ssh administration@10.1.0.189</code>
| |
| | |
| ==== Abfragen von Informationen vom Gerät ====
| |
| | |
| Anzeigen vom Status vom Gerät, besonders für stacking an<!-- vat@: Was ist los? -->
| |
| : <code>show version</code>
| |
| <nowiki>
| |
| Machine Description............... Dell EMC Networking Switch
| |
| System Model ID................... N4032
| |
| Machine Type...................... Dell Networking N4032
| |
| Serial Number..................... CN04G4FP282984AI0164A01
| |
| Manufacturer...................... 0xbc00
| |
| Burned In MAC Address............. F8B1.565B.6260
| |
| System Object ID.................. 1.3.6.1.4.1.674.10895.3042
| |
| CPU Version....................... XLP308H-B2
| |
| SOC Version....................... BCM56842_A1
| |
| HW Version........................ 3
| |
| CPLD Version...................... 17
| |
| Image File........................ N4000v6.5.4.21
| |
| Software Capability............... Stack Limit = 12, VLAN Limit = 4093
| |
| | |
| unit active backup current-active next-active
| |
| ---- ----------- ----------- -------------- --------------
| |
| 1 6.5.4.21 6.5.4.21 6.5.4.21 6.5.4.21
| |
| </nowiki>
| |
| | |
| Anzeigen vom Status vom Gerät, hinsichtlich der Verwendung als Stack
| |
| : <code>show switch</code>
| |
| <nowiki>
| |
| Management Standby Preconfig Plugged-in Switch Code
| |
| SW Status Status Model ID Model ID Status Version
| |
| --- ---------- --------- ------------- ------------- ------------- -----------
| |
| 1 Mgmt Sw N4032 N4032 OK 6.5.4.21
| |
| </nowiki>
| |
| | |
| Auflisten aller Kommandos
| |
| : <code>show ?</code>
| |
| <pre></pre>
| |
| | |
| Anzeigen aller Schnittstellen (Ports) mit dem aktuellen Status<!-- was ist mit "an auch Paketstatistiken und VLAN Informationen" gemeint? -->
| |
| : <code>show interfaces configuration</code>
| |
| <nowiki>
| |
| Port Description Duplex Speed Neg MTU Admin
| |
| State
| |
| --------- ------------------------------ ------ ------- ---- ----- -----
| |
| Te1/0/1 Full 1000 Auto 9216 Up
| |
| Te1/0/2 Full 1000 Auto 9216 Up
| |
| Te1/0/3 N/A Unknown Auto 9216 Up
| |
| Te1/0/4 N/A Unknown Auto 9216 Up
| |
| Te1/0/5 Full 1000 Auto 9216 Up
| |
| Te1/0/6 N/A Unknown Auto 9216 Up
| |
| Te1/0/7 N/A Unknown Auto 9216 Up
| |
| Te1/0/8 N/A Unknown Auto 9216 Up
| |
| Te1/0/9 N/A Unknown Auto 9216 Up
| |
| Te1/0/10 N/A Unknown Auto 9216 Up
| |
| Te1/0/11 N/A Unknown Auto 9216 Up
| |
| Te1/0/12 N/A Unknown Auto 9216 Up
| |
| Te1/0/13 N/A Unknown Auto 9216 Up
| |
| Te1/0/14 N/A Unknown Auto 9216 Up
| |
| Te1/0/15 N/A Unknown Auto 9216 Up
| |
| Te1/0/16 N/A Unknown Auto 9216 Up
| |
| Te1/0/17 N/A Unknown Auto 9216 Up
| |
| Te1/0/18 N/A Unknown Auto 9216 Up
| |
| Te1/0/19 N/A Unknown Auto 9216 Up
| |
| </nowiki>
| |
| | |
| Anzeigen der allgemeinen (aktuellen) Informationen vom System, wie Temperatur, Lüfter-Status und Stromversorgung<!-- vat@: wo steht hier was mit Strom? -->
| |
| : <code>show system</code>
| |
| <nowiki>
| |
| System Description: Dell EMC Networking Switch
| |
| System Up Time: 2 days, 20h:47m:53s
| |
| System Contact:
| |
| System Name:
| |
| System Location:
| |
| Burned In MAC Address: F8B1.565B.6260
| |
| System Object ID: 1.3.6.1.4.1.674.10895.3042
| |
| System Model ID: N4032
| |
| Machine Type: Dell Networking N4032
| |
|
| |
| System Thermal Conditions:
| |
|
| |
| Unit Temperature State
| |
| (Celsius)
| |
| ---- ----------- -----------
| |
| 1 53 Good
| |
| | |
| Temperature Sensors:
| |
| | |
| Unit Description Temperature
| |
| (Celsius)
| |
| ---- ------------------ -----------
| |
| 1 MAC 53
| |
| 1 CPU 51
| |
| 1 PHY (left side) 47
| |
| 1 PHY (right side) 49
| |
|
| |
| Fans:
| |
|
| |
| Unit Description Status
| |
| ---- ----------- -------------
| |
| 1 Fan-1 OK
| |
| 1 Fan-2 OK
| |
| 1 Fan-3 OK
| |
| 1 Fan-4 OK
| |
| 1 PS-1 Fan OK
| |
| 1 PS-2 Fan OK
| |
| </nowiki>
| |
| | |
| Anzeigen von Modelle (von Dell), die für die Verwendung als Stack unterstützt werden
| |
| : <code>show supported switchtype</code>
| |
| <nowiki>
| |
| SID Switch Model ID
| |
| --- --------------------------------
| |
| 1 N4032
| |
| 2 N4032F
| |
| 3 N4064
| |
| 4 N4064F
| |
| </nowiki>
| |
| | |
| Anzeigen der aktuellen (laufenden) Konfiguration
| |
| : <code>show running-config</code>
| |
| | |
| ==== Einrichtung Jumboframes ====
| |
| : Beim Einsatz von Ceph - was beim StuRa der Fall ist -, ist es nett Jumboframes zu verwenden.
| |
| | |
| Die maximale Größe von Frames für die Serie vom [[#Gerät]] (N4000) ist 9216.
| |
| | |
| <nowiki>
| |
| enable
| |
| configure
| |
| system jumbo mtu 9216
| |
| end
| |
| </nowiki>
| |
| | |
| <nowiki>
| |
| write
| |
| </nowiki>
| |
| | |
| ==== Einrichtung von bestimmten VLANs ====
| |
| : für Proxmox SDN
| |
| :: Wir möchten in Proxmox das mit v8.0 eingeführte SDN (Software defined networking) Feature verwenden. Im Cluster würde sich dafür entweder der VLAN oder der VxLAN Modus eignen. VxLAN funktioniert mit folgender Interface Konfiguration:
| |
| | |
| <nowiki>
| |
| configure
| |
| </nowiki>
| |
| | |
| Erstellung und Benamung von einem VLAN ''10''
| |
| <nowiki>
| |
| vlan 10
| |
| name "upstream"
| |
| exit
| |
| </nowiki>
| |
| | |
| Hinzufügen von der Schnittstelle ''1'' als eine gebündelte Schnittstelle (Trunk)
| |
| <nowiki>
| |
| interface Te1/0/1
| |
| switchport mode trunk
| |
| switchport general acceptable-frame-type tagged-only
| |
| exit
| |
| </nowiki>
| |
| | |
| Hinzufügen von der Schnittstelle ''2'' als eine gebündelte Schnittstelle (Trunk)
| |
| <nowiki>
| |
| interface Te1/0/2
| |
| switchport mode trunk
| |
| switchport general acceptable-frame-type tagged-only
| |
| exit
| |
| </nowiki>
| |
| | |
| Beschränkung (oder Erlauben?) vom Zugang bei der Schnittstelle ''5'' auf VLAN ''10'' (nur für das interne Netz)
| |
| <nowiki>
| |
| interface Te1/0/5
| |
| switchport access vlan 10
| |
| exit
| |
| </nowiki>
| |
| | |
| == Anschaffung ==
| |
| <!-- vat@ was here! :-) Happy 10-GBit/s party hard! -->
| |
| | |
| 2023
| |
| | |
| * [https://geizhals.de/a1539227.html geizhals.de ''Dell EMC Networking N Series PowerSwitch N4000 Rackmount 10G Managed Stack Switch, 24x RJ-45 N4032'']
| |
|
| |
|
| = Gerät 0 = | | = Gerät 0 = |
|
| |
|
| == Gerät 0 Ort == | | === Einstellungen vom Gerät 0 === |
| | |
| [[Serverschrank#schwarz]]
| |
| | |
| == Gerät 0 Einstellungen ==
| |
|
| |
|
| ; Reset: | | ; Reset: |
|
| |
|
| <s>Es fand (2023-11-17) ein pauschales Zurücksetzen der Einstellungen statt.</s> | | <s>Es fand (2023-11-17) ein pauschales Zurücksetzen der Einstellungen statt.</s> |
|
| |
| Setzen von Adressen für IP
| |
|
| |
| * (Deaktivierung vom Dienst telnet für die Anmeldung)
| |
| * Aktivierung vom Dienst SSH für die Anmeldung
| |
| *: [[#Einrichtung einer Anmeldung per SSH]]
| |
| * Aktivierung der Funktionalität für Jumboframes
| |
| ** Setzen der (größtmöglichen) Größe für Jumboframes
| |
| * Aktivierung der Funktionalität für VLAN
| |
| ** Setzen vom VLAN für eine bestimmte Schnittstelle (Port)
| |
| * Aktivierung der Funktionalität für Trunk (Bündelung/Zusammenfassung)
| |
| ** Bündeln von …
| |
|
| |
|
| = Gerät 1 = | | = Gerät 1 = |
|
| |
|
| === Gerät 1 Ort === | | === Einstellungen vom Gerät 1 === |
| | |
| <!--
| |
| Das Gerät machte einen Besuch beim [[C3D2]], zur Prüfung der Relevanz für eine Verwendung im [[Zentralwerk Dresden]].
| |
| Die Prüfung ergab, dass wegen der schlechten Möglichkeit zur Verwaltung - für die Konfiguration muss jeder Befehl muss einzeln gegeben werden - das Gerät nicht einfach mit NixOS verwaltet werden kann.
| |
| -->
| |
| unter [[Serverschrank#grau]]
| |
| | |
| === Gerät 1 Einstellungen ===
| |
|
| |
|
| ; Reset: | | ; Reset: |