StuRa:Server/srs5100: Unterschied zwischen den Versionen

Aus Wiki StuRa HTW Dresden
Zur Navigation springen Zur Suche springen
Zeile 102: Zeile 102:
Success
Success
</pre>
</pre>
reboot
reboot (durch [[w:de:Klammergriff|Affengriff]])
: <code></code>
<pre>C:\><pre>
: <code>sas2flsh.exe -o -f 6GBPSAS.fw</code>
<pre></pre>
<pre>
        Finished Processing Commands Successfully.
        Exiting SAS2Flash.
</pre>
<pre>C:\><pre>
: <code>s2fp19.exe -o -sasadd [[Intern:Server/Aktualisierung/2017#Dell PERC H200|5xxxxxxxxxxxxxxx]]</code>
:: Achtung! Mögliche ''-'' (Bindestriche) weglassen. (Es muss sich um eine 16-stellige hexadezimale Zahl handeln.)
<pre></pre>
<pre>
        Advanced Mode Set
 
        Adapter Selected is a LSI SAS: SAS2008(B2)
 
        Executing Operation: Program SAS Address
 
        SAS Address Successfully Programmed!
 
        Resetting Adapter...
        Adapter Successfully Reset
 
        Finished Processing Commands Successfully
        Exiting SAS2Flash.
</pre>
<pre>C:\><pre>


=== Wissen zum Gerät  ===
=== Wissen zum Gerät  ===

Version vom 23. Juni 2017, 22:10 Uhr

Gerät

hergestellt von
Dell
Modell
PowerEdge R510
Typ
Komponente Anzahl Bezeichnung
belegt belegbar
1 Mainboard 1
64 GB RAM 64 (2 x) 4 16 GB
1 CPU 1 2 Intel E5620 (2.40 GHz)
1 RAID

PERC H200

  • 8 x SAS/SATA
2 Netzwerk 2 2 1 GBit
10.0008.000 GB HDD 54 8 2.000 GB
2 Netzteil 2 2 750 W
iDRAC

Software für das Gerät

Dell Remote Access Controller

Siehe auch
wikipedia:en:Dell DRAC#iDRAC6

Nach dem Beginn der Stromversorgung ist der Controller nach (knapp unter) einer Minute (per ping) ansprechbar. Offiziell wird von Dell angegeben, dass das Initialisieren (bis zu) zwei Minuten dauern kann.

Dell PERC H200

sas2flsh.exe -listall
SAS2008(??)
00:02:00:00
sas2flsh.exe -c 0 -list

Intern:Server/Aktualisierung/2017#Dell PERC H200

megarec.exe -writesbr 0 sbrempty.bin
 Chip is in FUSION mode

Success
megarec.exe -cleanflash 0
Erasing Flash Chip (8 MB)...
 Completed: 100%

Success

reboot (durch Affengriff)

C:\><pre>
: <code>sas2flsh.exe -o -f 6GBPSAS.fw</code>
<pre>
        Finished Processing Commands Successfully.
        Exiting SAS2Flash.
C:\><pre>
: <code>s2fp19.exe -o -sasadd [[Intern:Server/Aktualisierung/2017#Dell PERC H200|5xxxxxxxxxxxxxxx]]</code>
:: Achtung! Mögliche ''-'' (Bindestriche) weglassen. (Es muss sich um eine 16-stellige hexadezimale Zahl handeln.)
<pre>
        Advanced Mode Set

        Adapter Selected is a LSI SAS: SAS2008(B2)

        Executing Operation: Program SAS Address

        SAS Address Successfully Programmed!

        Resetting Adapter...
        Adapter Successfully Reset

        Finished Processing Commands Successfully
        Exiting SAS2Flash.
C:\>

Wissen zum Gerät

* Knowledge Base Support Articles for Dell PowerEdge Servers

Anschaffung

Fehlerbehebung

Unterbrechung beim Starten wegen dem Vermerk eines Problems bei der Stromversorgung

; gelöst! Das Problem ergab sich wohl durch das Zurücksetzen vom BIOS (auf die Voreinstellungen). (Danach wurde der Server nicht vom Strom getrennt.) * Dell: Knowledge Base: Problembehebung

minimale Taktung beim Arbeitsspeicher

; ungelöst! Nach dem Einsetzen vom 4. Riegel (16 GB, 1.333 MHz) in den dafür vorgesehen Slot (A4, schwarze Klammern) wird der (gesamte) Arbeitsspeicher (statt zuvor 1.067 MHz) nur noch mit 800 MHz betrieben.

Siehe auch

* Server