<code>cd FTS_iRMCS2Kronos2FirmwareRX300S6ASPforLin_RX300S6577Asdr031510_1166673</code> | <code>cd FTS_iRMCS2Kronos2FirmwareRX300S6ASPforLin_RX300S6577Asdr031510_1166673</code> | ||
<code>sudo yum install -y libstdc++.i686</code> | <code>sudo yum install -y libstdc++.i686</code> | ||
Zeile 164: | Zeile 163: | ||
: Auto - Firmware image with highest Firmware version | : Auto - Firmware image with highest Firmware version | ||
: Apply | : Apply | ||
== Aktualisierung RAID D2507-C FSC RX300 S6 == | |||
: LSI SAS IME Flash Firmware 1068E on Controller LSI RAID 0/1 SAS 8P | |||
: (D2507-A)(D2507-C) | |||
* https://support.ts.fujitsu.com/IndexDownload.asp?SoftwareGuid=8C54E6B8-A8A4-4209-B82D-19F0DC2170C1 | |||
* ''zip'' entpacken | |||
<code>cd </code> | |||
<code>sudo yum install -y libstdc++.i686</code> | |||
<code>sudo sh …</code> | |||
<pre> | |||
Continue processing this ASP? | |||
Please answer: yes/y or no/n | |||
</pre> | |||
<pre> | |||
y | |||
</pre> | |||
<pre> | |||
</pre> | |||
== Aktualisierung mit ServerView == | == Aktualisierung mit ServerView == |
Version vom 18. Juli 2018, 04:31 Uhr
Aktualisierung BIOS FSC RX300 S6
Die Aktualisierung wurde nicht bei der Hardware Server/srs3006 vorgenommen. Die Aktualisierung wurde bei vergleichbarer Hardware FSC RX300 S6 vorgenommen.
sudo yum update -y
- https://support.ts.fujitsu.com/Index.asp?lng=en&OICOpen=Servers
- https://support.ts.fujitsu.com/Index.asp?lng=de&OICOpen=Servers
I have read and agree to the terms and conditions.
cd ~/Downloads/
sudo yum install -y libstdc++.i686
sudo yum install -y gcc
sudo yum install -y kernel-devel-2.6.32-754.el6.x86_64
sudo sh FTS_FlashBIOSRX300S6ASPforLinux_600114100_1199124.SCEXE
***************** PRIMERGY Autonomous Support Package *************** Description: Flash BIOS RX300 S6 VersionMajor: 6.00 VersionMinor: 1.14 VersionBuild: 1.0.0 Software Class - Category: Flash - BIOS Software Class - Name: (SV) Flash Bios Vendor: Fujitsu ********************************************************************* Continue processing this ASP? Please answer: yes/y or no/n
y
********************************************************************* CAUTION! Currently a new version is being installed. The installation process will take a long time. .... please wait .... Don't interrupt this installation process! ********************************************************************* ********************************************************************* SUCCESS! A new version was successfully installed. For activating the new version, please reboot your system. *********************************************************************
Aktualisierung iRMC FSC RX300 S6
- zip entpacken
cd FTS_iRMCS2Kronos2FirmwareRX300S6ASPforLin_RX300S6577Asdr031510_1166673
sudo yum install -y libstdc++.i686
sudo sh RX300S6_MangtCtr_FW0577_SDR315.scexe
***************** PRIMERGY Autonomous Support Package *************** Description: iRMC S2 (Kronos2) Firmware - RX300 S6 VersionMajor: RX300S6_5.77A_sdr03.15 VersionBuild: 1.0.0 Software Class - Category: Flash - Firmware Software Class - Name: (SV) Flash - Firmware Vendor: Fujitsu Technology Solutions ********************************************************************* Continue processing this ASP? Please answer: yes/y or no/n
y
********************************************************************* CAUTION! Currently a new version is being installed. The installation process will take a long time. .... please wait .... Don't interrupt this installation process! ********************************************************************* ********************************************************************* SUCCESS! A new version was successfully installed. For activating the new version, please reboot your system. *********************************************************************
- iRMC -> RMC S2 -> iRMC S2 Information -> Running Firmware
Firmware Version: 5.77A (Base: V3.10A8P2) Firmware Date: Jun 30 2016 - 08:33:56 Firmware Running: Low Firmware Image Hardware Version: 2 Chip ID: 04 E5 34 12 9D 01 60 SDRR Version: 3.15 ID 0263 RX300S6
Firmware Version: 5.76A (Base: V3.10A8P2) Firmware Date: Jan 9 2015 - 13:12:33 Firmware Running: High Firmware Image Hardware Version: 2 Chip ID: 04 E5 34 12 9D 01 60 SDRR Version: 3.15 ID 0263 RX300S6
- iRMC -> iRMC S2 -> iRMC S2 Update -> Firmware Image Information
- Firmware Selector
- Auto - Firmware image with highest Firmware version
- Apply
Aktualisierung RAID D2507-C FSC RX300 S6
- LSI SAS IME Flash Firmware 1068E on Controller LSI RAID 0/1 SAS 8P
- (D2507-A)(D2507-C)
- zip entpacken
cd
sudo yum install -y libstdc++.i686
sudo sh …
Continue processing this ASP? Please answer: yes/y or no/n
y
Aktualisierung mit ServerView
Installation ServerView
- Hinweis
- Die (klassische) Installation - im Unterschied zu einem Live-System mit standardmäßig arg begrenzter weiterer Kapazität an Platz für größere Dateien - ist angeraten.
rpm -U srvmagt-mods_src-<version>-<release>.<arch>.rpm rpm -U ServerViewConnectorService-<version>-<release>.<arch>.rpm rpm -U srvmagt-eecd-<version>-<release>.<arch>.rpm rpm -U srvmagt-agents-<version>-<release>.<arch>.rpm rpm -U srv-cimprovider-<version>-<release>.x86_64.rpm rpm -U SSMWebUI-<version>-<release>.noarch.rpm