| == Gerät ==
| |
|
| |
| ; hergestellt von: Dell
| |
| ; Modell: [[wikipedia:en:List of Dell PowerEdge Servers#Generation 11 | PowerEdge]] [http://www.dell.com/en-us/work/shop/productdetails/poweredge-r510 R510]
| |
| ; Typ:
| |
|
| |
| {| class="wikitable"
| |
| |-
| |
| ! rowspan="2" |
| |
| ! rowspan="2" | Komponente
| |
| ! colspan="2" | Anzahl
| |
| ! rowspan="2" | Eigenschaften
| |
| |-
| |
| ! belegt
| |
| ! belegbar
| |
| |-
| |
| | 1
| |
| | Mainboard
| |
| | colspan="2" style="text-align:right" | 1
| |
| |
| |
| |-
| |
| | 16 GB
| |
| | RAM
| |
| | style="text-align:right"| <s>8 </s>4
| |
| | style="text-align:right"| <s>(2 ·) </s>4
| |
| | 4 GB<!--
| |
| ---- bitte berichtigen
| |
| PC3-10600 ECC
| |
| !-->
| |
| |-
| |
| | 1
| |
| | CPU
| |
| | style="text-align:right"| 1
| |
| | style="text-align:right"| 2
| |
| | [http://ark.intel.com/products/47925 Intel E5620 (2.40 GHz)]
| |
| |-
| |
| | 1
| |
| | RAID
| |
| | colspan="2" style="text-align:right"|
| |
| |
| |
| [http://www.dell.com/learn/us/en/04/campaigns/dell-raid-controllers PERC] [http://www.dell.com/support/article/us/en/04/SLN156304 H200]
| |
| * 2 · 4 · SAS/SATA
| |
| * mit [[#Änderung der Firmware vom RAID Controller Dell PERC H200|#geänderter Firmware]]
| |
| |-
| |
| | 2
| |
| | Netzwerk
| |
| | style="text-align:right"| 2
| |
| | style="text-align:right"| 2
| |
| | 1 GBit
| |
| |-
| |
| | <s>10.000</s><br />8.000 GB
| |
| | HDD
| |
| | style="text-align:right" | <s>5</s><br />4
| |
| | style="text-align:right" | 8
| |
| |
| |
| * SATA
| |
| * 2.000 GB
| |
| |-
| |
| | 2
| |
| | Netzteil
| |
| | style="text-align:right" | 2
| |
| | style="text-align:right" | 2
| |
| | 750 W
| |
| |-
| |
| | 2
| |
| | USB-Stick
| |
| | style="text-align:right" colspan="2"| 2
| |
| | 16 GB (SanDisk)
| |
| |-
| |
| |}
| |
|
| |
| ; [[#Dell Remote Access Controller|iDRAC]]
| |
|
| |
| === Software für das Gerät ===
| |
|
| |
| * [http://www.dell.com/support/home/us/en/04/product-support/product/poweredge-r510/research Dell: Support for PowerEdge R510]
| |
| ** [http://www.dell.com/support/home/us/en/04/product-support/product/poweredge-r510/drivers Dell: Support for PowerEdge R510 ''Optimize your system with drivers and updates.'']
| |
|
| |
| === Dell Remote Access Controller ===
| |
| ; Siehe auch:
| |
| : [[wikipedia:en:Dell DRAC#iDRAC6]]
| |
|
| |
| * [http://www.dell.com/support/article/SLN300677 Knowledge Base ''How-To Dell Server : iDRAC and CMC Support Articles'']
| |
|
| |
| ==== Einstellungen vom Dell Remote Access Controller ====
| |
|
| |
| ; Reset:
| |
|
| |
| Es fand (<s>2017-07-02</s>2017-12-09) ein pauschales Zurücksetzen der Einstellungen statt.
| |
|
| |
| * Beim Starten die Gelegenheit "Ctrl" + "e" genutzt.
| |
|
| |
| * ''Reset To Default''
| |
| * ''< YES (Continue) >''
| |
| * Prozess abgewartet
| |
| <pre>
| |
| </pre>
| |
| <pre>
| |
| Settings successfully restored to defaul.
| |
| Press any key to continue ...
| |
| </pre>
| |
| * bestätigt
| |
|
| |
| * ''System Event Log Menu''
| |
| * ''Clear System Event Log''
| |
| * ''< YES (Continue) >''
| |
|
| |
| ; LAN Parameters:
| |
| :; IPv4 Adress: [[Intern:Server#Verwendung von IP-Adressen]]
| |
| :; Default Gateway: 141.56.50.254
| |
| :; DNS Server 1: 141.56.1.1
| |
| :; DNS Server 2: 141.56.1.2
| |
| ; LAN User Configuration:
| |
| :; Account User Name: [[Intern:Server#Zugangsdaten]]
| |
| :; Enter Password: [[Intern:Server#Zugangsdaten]]
| |
| :; Confirm Password: [[Intern:Server#Zugangsdaten]]
| |
|
| |
| ; IPMI Over LAN: On
| |
|
| |
| Verlassen
| |
| ; Save Changes and Exit
| |
| * bestätigt
| |
|
| |
| ===== Einstellungen vom Dell Remote Access Controller (per web user intface) =====
| |
|
| |
| ; System:
| |
| :; Alerts:
| |
| ::; Email Alert Setting:
| |
| :::; Email Alert 1:
| |
| ::::; Destination Email Address: srs5100@stura.htw-dresden.de
| |
| :::; SMTP (e-mail) Server IP Address or FQDN / DNS Name: mail.stura.htw-dresden.de
| |
|
| |
| ==== Neustarten vom Dell Remote Access Controller ====
| |
|
| |
| Nach dem Beginn der Stromversorgung ist der Controller nach (knapp unter) einer Minute (per <code>ping</code>) ansprechbar. Offiziell wird von Dell angegeben, dass das Initialisieren (bis zu) zwei Minuten dauern kann.
| |
|
| |
| ==== LCD Front Panel Display ====
| |
|
| |
| === BIOS ===
| |
|
| |
| ==== Einstellungen beim BIOS ====
| |
|
| |
| Wie kann das BIOS auf Voreinstellungen zurückgestellt werden?
| |
|
| |
| === Dell PERC H200 ===
| |
|
| |
| ==== Änderung der Firmware vom RAID Controller Dell PERC H200 ====
| |
|
| |
| ; Wieso?
| |
|
| |
| Es soll das Dateisystem ZFS (einfach, funktional, stabil: zeitgemäß) verwendet werden. Dabei stört das "Reinpfuschen" von einem Controller. Es soll für ZFS der direkteste Zugriff auf den Speicher möglich sein.
| |
|
| |
| Die standardmäßige Firmware vom ''PERC H200'' bietet aber (für die Verwendung von ZFS) ungewollte Funktionalität, RAID per Hardware. Ein schlichtest "Durchreichen" gibt es (als Funktionalität) nicht. Doof!
| |
|
| |
| Es muss daher eine "einfachere" Firmware verwendet werden. Die Firmware muss dann (für den Chip) auf den (Chip vom) Controller "gepresst" (flashing) werden. (Im Übrigen geht das leider nicht bei allen RAID Controllern. Beim PERC H200 soll das aber funktionieren.)
| |
|
| |
| ; Wonach?
| |
|
| |
| Es gibt verschiedene Anleitung für das Flashing.
| |
|
| |
| Als Anleitung wurde [https://techmattr.wordpress.com/2016/04/11/updated-sas-hba-crossflashing-or-flashing-to-it-mode-dell-perc-h200-and-h310/ TECHMATTR ''Updated: SAS HBA crossflashing or flashing to IT mode, Dell Perc H200 and H310''] erfolgreich verwendet.
| |
|
| |
| ; Wie?
| |
|
| |
| :; Vorbereitung:
| |
|
| |
| Erstellen vom Speichermedium (FreeDOS, Programme zur Verwaltung der Firmware, Dateien der Firmware), wovon gestartet werden kann, per USB-Stick
| |
|
| |
| Bei der nachfolgenden Durchführung wird immer vom Speichermedium gestartet. (Dazu muss beim Server eingestellt (oder ausgewählt) werden, dass vom Speichermedium (USB-Stick) gestartet wird.)
| |
|
| |
| :; Durchführung:
| |
|
| |
| Starten!
| |
| <pre>C:\></pre>
| |
| : <code>sas2flsh.exe -listall</code>
| |
| <pre>
| |
| SAS2008(??)
| |
| </pre>
| |
| <pre>
| |
| 00:02:00:00
| |
| </pre>
| |
| <pre>C:\></pre>
| |
| : <code>sas2flsh.exe -c 0 -list</code>
| |
| [[Intern:Server/Aktualisierung/2017#Dell PERC H200]]
| |
| <pre>C:\></pre>
| |
| : <code>megarec.exe -writesbr 0 sbrempty.bin</code>
| |
| <pre></pre>
| |
| <pre>
| |
| Chip is in FUSION mode
| |
|
| |
| Success
| |
| </pre>
| |
| <pre>C:\></pre>
| |
| : <code>megarec.exe -cleanflash 0</code>
| |
| <pre></pre>
| |
| <pre>
| |
| Erasing Flash Chip (8 MB)...
| |
| Completed: 100%
| |
|
| |
| Success
| |
| </pre>
| |
| <pre>C:\></pre>
| |
| Neustarten! (durch [[w:de:Klammergriff|Affengriff]])
| |
| <pre>C:\></pre>
| |
| : <code>sas2flsh.exe -o -f 6GBPSAS.fw</code>
| |
| <pre></pre>
| |
| <pre>
| |
| Finished Processing Commands Successfully.
| |
| Exiting SAS2Flash.
| |
| </pre>
| |
| <pre>C:\></pre>
| |
| : <code>s2fp19.exe -o -sasadd [[Intern:Server/Aktualisierung/2017#Dell PERC H200|5xxxxxxxxxxxxxxx]]</code>
| |
| :: Achtung! Mögliche ''-'' (Bindestriche) weglassen. (Es muss sich um eine 16-stellige hexadezimale Zahl handeln.)
| |
| <pre></pre>
| |
| <pre>
| |
| Advanced Mode Set
| |
|
| |
| Adapter Selected is a LSI SAS: SAS2008(B2)
| |
|
| |
| Executing Operation: Program SAS Address
| |
|
| |
| SAS Address Successfully Programmed!
| |
|
| |
| Resetting Adapter...
| |
| Adapter Successfully Reset
| |
|
| |
| Finished Processing Commands Successfully.
| |
| Exiting SAS2Flash.
| |
| </pre>
| |
| <pre>C:\></pre>
| |
| Neustarten! (durch [[w:de:Klammergriff|Affengriff]])
| |
| <pre>C:\></pre>
| |
| : <code>as2flsh.exe -o -f 2118it.bin</code>
| |
| <pre></pre>
| |
| <pre>
| |
| Advanced Mode Set
| |
|
| |
| Adapter Selected is a LSI SAS: SAS2008(??)
| |
|
| |
| Executing Operation: Flash Firmware Image
| |
| </pre>
| |
| <pre></pre>
| |
| <pre>
| |
| NVDATA Product ID and Vendor ID do not match.
| |
| Would you like to flash anyway [y/n]? y
| |
| </pre>
| |
| <pre></pre>
| |
| <pre>
| |
| Firmware Flash Successful!
| |
|
| |
| Resetting Adapter...
| |
| Adapter Successfully Reset</pre>
| |
|
| |
| Finished Processing Commands Successfully.
| |
| Exiting SAS2Flash.
| |
| <pre>C:\></pre>
| |
| Neustarten! (durch [[w:de:Klammergriff|Affengriff]])
| |
|
| |
| === Wissen zum Gerät ===
| |
|
| |
| * [http://www.dell.com/support/article/us/en/04/SLN299023 Knowledge Base ''Support Articles for Dell PowerEdge Servers'']
| |
|
| |
| == Anschaffung ==
| |
|
| |
| * 2017-06
| |
| * "gespendet" bekommen
| |
| * etwaiger Zeitwert (durch angenommene Wiederbeschaffung) zum Anschaffungszeitpunkt
| |
| *: Gerät
| |
| *:* 350 €
| |
| *: Massenspeicher (4 (3.5 ″) x 2 TB)
| |
| *:* 400 € (4 x [https://www.kimbrer.de/dell-r755k.html 100 €])
| |
|
| |
| [[v]] hat das [[#Gerät]] "angefunden"<!-- Es wurde privat gezahlt. --> Dabei kamen auch [[Cisco SRW20#Cisco SRW2024]] und [[Cisco SRW20#Cisco SRW2048]] mit.
| |
|
| |
| Motivation war der dringliche Bedarf an (nennenswert viel) Speicherplatz, da sich [[srs3006]]<s> oder [[srs3005]]</s> kurzfristig (wegen 12 x 2.5 ″) als nicht gut geeignet herausstellten. (RAID mit SAS Expander und ZFS ist doof. 2.5 ″ (SAS als auch SATA) kosten selbst gebraucht nennenswert viel mehr.)
| |
|
| |
| == Fehler ==
| |
|
| |
| : Fehler, die sich bei der Hardware ohne unabhängig vom [[#Betriebssystem]] sind
| |
| : Fehler, die sich durch beim [[#Betriebssystem]] ergeben: siehe [[#Fehler bei FreeNAS]]
| |
|
| |
| ==== <s>Unterbrechung beim Starten wegen dem Vermerk eines Problems bei der Stromversorgung</s> ====
| |
|
| |
| ; gelöst!
| |
|
| |
| Das Problem ergab sich wohl durch das Zurücksetzen vom BIOS (auf die Voreinstellungen). (Danach wurde der Server nicht vom Strom getrennt.)
| |
|
| |
| * [http://www.dell.com/support/article/de/de/debsdt1/SLN266092/ Dell: Knowledge Base: Problembehebung]
| |
|
| |
| ==== minimale Taktung beim Arbeitsspeicher ====
| |
|
| |
| ; ungelöst!
| |
|
| |
| Nach dem Einsetzen vom 4. Riegel (16 GB, 1.333 MHz) in den dafür vorgesehen Slot (A4, schwarze Klammern) wird der (gesamte) Arbeitsspeicher (statt zuvor 1.067 MHz) nur noch mit 800 MHz betrieben.
| |
|
| |
| == Betriebssystem == | | == Betriebssystem == |
|
| |
|
Betriebssystem
FreeNAS 11 (RELEASE)
Installation von FreeNAS
Vorbereitung der Installation von FreeNAS
Die (Vorbereitung der) Installation von FreeNAS[1] erfolgt eigentlich schlichtweg durch
- das [2]Beziehen von einer iso-Datei, welche schon als startfähig vorbereitet ist,
- das [3]Erstellen von einem Startmedium mit der iso-Datei und
- das Starten von dem Startmedium auf der Maschine, wo FreeNAS betrieben werden soll.
Durchführung der Installation von FreeNAS
2017-07-02 22:23:24
Chose destination media
[ ] da0 ATA
[ ] da1 ATA
[ ] da2 ATA
[ ] da3 ATA
[*] da5 Intenso
Fresh Install
Format the boot device
FreeNAS installation
Yes
Password
- Intern:Server#Zugangsdaten
Confirm Password
- Intern:Server#Zugangsdaten
OK
FreeNAS Boot Mode
Boot via BIOS
Installation finished. No error reported.
The FreeNAS installation on da5 succeeded!
OK
3 Reboot
OK
Rebooting...
Einrichtung nach der Installation von FreeNAS
- Initial Wizard
- Time Zone
- Europe/Berlin
- Pool
- back
[ ] Automatic (Reasonable defaults using the available drives)
[ ] Virtualization (RAID 10: Moderate Redundancy, Maximum Performance, Minimum Capacity)
[X] Backups (RAID Z2: Moderate Redundancy, Moderate Performance, Moderate Capacity)
[ ] Media (RAID Z1: Minimum Redundancy, Moderate Performance, Moderate Capacity)
[ ] Logs (RAID 0: No Redundancy, Maximum Performance, Maximum Capacity)
erstes Starten nach der Installation von FreeNAS
Start nach der Installation
11) Rebbot
The web interfache could not be accessed.
Please check network configuration.
Enter an option from 1-12: 11
Shutdown NOW!
Rebooting...
(erneuter) Start nach der Installation
The web interfache is at:
http://141.56.50.DHCP
FreeNAS Einstellungen (per command line interface)
nichts!
FreeNAS Einstellungen (per web user intface)
Anmelden per web user intface
- http://141.56.50.DHCP
- System
-
- Information
- Edit
- Hostname
- srs5100.stura.htw-dresden.de
- OK
- General
-
- Timezone
- Europe/Berlin
- Save
- Advanced
-
- Enable powerd (Power Saving Daemon)
- X
- Show console messages in the footer
- X
- Enable autotune
- X
- MOTD banner
Welcome to FreeNASsrs5100.stura.htw-dresden.de
- Save
- Email
-
- From email
- srs5100@stura.htw-dresden.de
- Outgoing mail server
- mail.stura.htw-dresden.de
- HINT: Test e-mails are sent to root user. To configure it use Account -> Users -> View Users -> root -> Change E-mail
- Save
pauschales Neustarten (wegen Änderung der Einstellungen zu powerd und autotune)!
- Network
-
- Global Configuration
-
- IPv4 Default Gateway
- 141.56.50.254
- Nameserver 1
- 141.56.1.1
- Nameserver 2
- 141.56.1.2
- Save
- Interfaces
- Es gibt keinen Eintrag (trotz Verbindung mit IPv4 per DHCP)
- Add
- NIC
- bce0
- Interface Name
- bce0-stat
- IPv4 Address
- 141.56.50.124
- IPv4 Netmask
- /24 (255.255.255.0)
- Save
- Keine Erreichbarkeit mehr!
- Damn!
- Es stellte sich heraus, dass die Nase vom Netzwerkkabel am Switch nicht richtig eingerastet war. (DAMN!)
- Import vom existierende (wohl leeren) zpool back
- Bei den Tests zuvor wurde bereits bei den bestehenden Festplatten ein zpool back erstellt. (Anstatt unnötig einen neuen Pool aus dem getesteten zpool (mit 4 Geräten) zu erstellen, wurde dieser einfach weiter verwendet.)
- Account
-
- Users
-
- root
-
- E-mail
- srs5100@stura.htw-dresden.de
- OK
Konfiguration von FreeNAS
- Services
-
- SSH
-
- Settings
-
- Login as Root with password
- X
- Allow TCP Port Forwarding
- X
- Compress Connections
- X
- Start on boot
- X
- Start Now
- Jails
-
- Configuration
-
- Jail Root
- /mnt/back/jails
- Save
Fehler bei FreeNAS
- Fehler, die bei (dem Betrieb von) FreeNAS erkennbar sind
- Fehler der Hardware, die sich unabhängig vom #Betriebssystem ergeben: siehe #Fehler
Wartung von FreeNAS
Neustarten von FreeNAS
Das Starten (samt BIOS und Firmware bis zur direkten Erreichbarkeit von FreeNAS) dauert es etwa 5 min.
Ablage
- Verwaltung von Daten (zur Ablage an bestimmten Orten)
- Siehe auch
- Server/srs1337#Storage
einzelne Ablagen
dataset
|
(ergänzender) Einhängepunkt
|
Zweck
|
zpool back
|
|
|
|
Erstellung einer einzelnen Ablage
- Storage
-
- übergeordnetes Dataset
- Create Dataset
- ...
Einhängen einer einzelnen Ablage
- üblicher Weise in eine Jail
- Jails
-
- Storage
-
- Add Storage
-
- ...
Siehe auch