Aktualisierung BIOS FSC RX300 S6

Die Aktualisierung wurde nicht bei der Hardware Server/srs3006 vorgenommen.
Die Aktualisierung wurde bei vergleichbarer Hardware FSC RX300 S6 vorgenommen.

sudo yum update -y


I have read and agree to the terms and conditions.

cd ~/Downloads/

sudo yum install -y libstdc++.i686

sudo yum install -y gcc

sudo yum install -y kernel-devel-2.6.32-754.el6.x86_64

sudo sh FTS_FlashBIOSRX300S6ASPforLinux_600114100_1199124.SCEXE

***************** PRIMERGY Autonomous Support Package ***************

Description: Flash BIOS RX300 S6  
VersionMajor: 6.00                
VersionMinor: 1.14                
VersionBuild: 1.0.0               
Software Class - Category: Flash - BIOS 
Software Class - Name: (SV) Flash Bios
Vendor: Fujitsu

*********************************************************************

Continue processing this ASP?
Please answer: yes/y or no/n
y
*********************************************************************


                          CAUTION!

         Currently a new version is being installed.

       The installation process will take a long time.

                   .... please wait ....

          Don't interrupt this installation process!



*********************************************************************
*********************************************************************


                        SUCCESS!

             A new version was successfully installed.

    For activating the new version, please reboot your system.



*********************************************************************

Aktualisierung iRMC FSC RX300 S6

cd FTS_iRMCS2Kronos2FirmwareRX300S6ASPforLin_RX300S6577Asdr031510_1166673

sudo sh RX300S6_MangtCtr_FW0577_SDR315.scexe

 

***************** PRIMERGY Autonomous Support Package ***************

Description: iRMC S2 (Kronos2) Firmware - RX300 S6  
VersionMajor: RX300S6_5.77A_sdr03.15
VersionBuild: 1.0.0
Software Class - Category: Flash - Firmware 
Software Class - Name: (SV) Flash - Firmware 
Vendor: Fujitsu Technology Solutions 

*********************************************************************

Continue processing this ASP?
Please answer: yes/y or no/n
y
*********************************************************************


                          CAUTION!

         Currently a new version is being installed.

       The installation process will take a long time.

                   .... please wait ....

          Don't interrupt this installation process!



*********************************************************************

Aktualisierung mit ServerView

Installation ServerView

Hinweis
Die (klassische) Installation - im Unterschied zu einem Live-System mit standardmäßig arg begrenzter weiterer Kapazität an Platz für größere Dateien - ist angeraten.
                rpm -U srvmagt-mods_src-<version>-<release>.<arch>.rpm
                rpm -U ServerViewConnectorService-<version>-<release>.<arch>.rpm
                rpm -U srvmagt-eecd-<version>-<release>.<arch>.rpm
                rpm -U srvmagt-agents-<version>-<release>.<arch>.rpm
                rpm -U srv-cimprovider-<version>-<release>.x86_64.rpm
                rpm -U SSMWebUI-<version>-<release>.noarch.rpm